Overview
In this article I will demonstrate how to patch or upgrade Oracle Exadata IB Switches.
About Infiniband Switch Patching
Environment
Step by Step Infiniband Switch Patching
Conclusion
In this article we have demonstrated how to patch Exadata IB Switches using patchmgr utility. Patching an Exadata IB switch is very straight forward and can be done in rolling fashion without any downtime.
- The Exadata network grid consists of multiple Sun QDR InfiniBand switches.
- IB Switches are used for the storage network as well as the Oracle RAC interconnect.
- Exadata compute nodes and storage cells are configured with dual-port InfiniBand ports and connect to each of the two leaf switches.
- You can access IB Switches using command line and Web ILOM
- IB Switches run Linux operating system.
In this article I will demonstrate how to patch or upgrade Oracle Exadata IB Switches.
About Infiniband Switch Patching
- Starting with release 11.2.3.3.0, the patchmgr utility is used to upgrade and downgrade the InfiniBand switches.
- IB Switch patch is delievered with Exadata storage patch.
- IB Switch patches are released semi annually to annually.
- IB Switch can be patched in Rolling fashion only.
Environment
- Exadata Half Rack X4-2
- 4 Compute nodes, 7 Storage cells and 2 IB Switches
- Current IB Switch Version 2.2.7-1
Step by Step Infiniband Switch Patching
- Identify the number of switches in clusters.
[root@dm01dbadm01 ~]# ibswitches
Switch : 0x002128469b8aa0a0 ports 36 "SUN DCS 36P QDR dm01sw-iba01 10.209.41.246" enhanced port 0 lid 5 lmc 0
Switch : 0x002128469b97a0a0 ports 36 "SUN DCS 36P QDR dm01sw-ibb01 10.209.41.247" enhanced port 0 lid 4 lmc 0
Switch : 0x002128469b8aa0a0 ports 36 "SUN DCS 36P QDR dm01sw-iba01 10.209.41.246" enhanced port 0 lid 5 lmc 0
Switch : 0x002128469b97a0a0 ports 36 "SUN DCS 36P QDR dm01sw-ibb01 10.209.41.247" enhanced port 0 lid 4 lmc 0
- Identify the current IB switch software version on all the Switches
[root@dm01db01 patch_18.1.12.0.0.190111]# ssh dm01sw-iba01 version
SUN DCS 36p version: 2.2.7-1
Build time: Aug 4 2017 12:20:53
SP board info:
Manufacturing Date: 2014.05.20
Serial Number: "NCDFxxxxx"
Hardware Revision: 0x0107
Firmware Revision: 0x0000
BIOS version: SUN0R100
BIOS date: 06/22/2010
SUN DCS 36p version: 2.2.7-1
Build time: Aug 4 2017 12:20:53
SP board info:
Manufacturing Date: 2014.05.20
Serial Number: "NCDFxxxxx"
Hardware Revision: 0x0107
Firmware Revision: 0x0000
BIOS version: SUN0R100
BIOS date: 06/22/2010
- Log in to Exadata Compute node 1 as root user and navigate the Exadata Storage Software staging area
[root@dm01dbadm01 ESS_121220]# cd /u01/app/oracle/software/exa_patches/patch_18.1.12.0.0.190111
[root@dm01dbadm01 patch_18.1.12.0.0.190111]# pwd
/u01/app/oracle/software/exa_patches/patch_18.1.12.0.0.190111
/u01/app/oracle/software/exa_patches/patch_18.1.12.0.0.190111
- Create a file named ibswitches.lst and enter IB switch names one per line as follows:
[root@dm01dbadm01 patch_18.1.12.0.0.190111]# vi ~/ibswitch_group
dm01sw-ibb01
dm01sw-iba01
[root@dm01dbadm01 patch_18.1.12.0.0.190111]# cat ~/ibswitch_group
dm01sw-ibb01
dm01sw-iba01
dm01sw-ibb01
dm01sw-iba01
[root@dm01dbadm01 patch_18.1.12.0.0.190111]# cat ~/ibswitch_group
dm01sw-ibb01
dm01sw-iba01
- Execute the following to perform the IB Switch precheck
[root@dm01db01 patch_18.1.12.0.0.190111]# ./patchmgr -ibswitches ~/ibswitch_group -upgrade -ibswitch_precheck
2019-02-10 03:02:46 -0600 1 of 1 :Working: DO: Initiate pre-upgrade validation check on InfiniBand switch(es).
----- InfiniBand switch update process started 2019-02-10 03:02:47 -0600 -----
[NOTE ] Log file at /u01/app/oracle/software/exa_patches/patch_18.1.12.0.0.190111/upgradeIBSwitch.log
[INFO ] List of InfiniBand switches for upgrade: ( dm01sw-ibb01 dm01sw-iba01 )
[SUCCESS ] Verifying Network connectivity to dm01sw-ibb01
[SUCCESS ] Verifying Network connectivity to dm01sw-iba01
[SUCCESS ] Validating verify-topology output
[INFO ] Master Subnet Manager is set to "dm01sw-ibb01" in all Switches
[INFO ] Upgrade to 2.2.11_2 requires that the InfiniBand switch be at 2.2.7-2. Upgrading dm01sw-ibb01 first to 2.2.7-2
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-ibb01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-ibb01.
[INFO ] Starting pre-update validation on dm01sw-ibb01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-ibb01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-ibb01, found 26M
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:03:03
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-ibb01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-ibb01
[INFO ] Finished pre-update validation on dm01sw-ibb01
[SUCCESS ] Pre-update validation on dm01sw-ibb01
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-ibb01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-ibb01.
[INFO ] Starting pre-update validation on dm01sw-ibb01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-ibb01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-ibb01, found 26M
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:03:34
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-ibb01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-ibb01
[INFO ] Finished pre-update validation on dm01sw-ibb01
[SUCCESS ] Pre-update validation on dm01sw-ibb01
[SUCCESS ] Prereq check on dm01sw-ibb01
[INFO ] Upgrade to 2.2.11_2 requires that the InfiniBand switch be at 2.2.7-2. Upgrading dm01sw-iba01 first to 2.2.7-2
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-iba01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-iba01.
[INFO ] Starting pre-update validation on dm01sw-iba01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-iba01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-iba01, found 26M
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:04:06
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-iba01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-iba01
[INFO ] Finished pre-update validation on dm01sw-iba01
[SUCCESS ] Pre-update validation on dm01sw-iba01
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-iba01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-iba01.
[INFO ] Starting pre-update validation on dm01sw-iba01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-iba01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-iba01, found 26M
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:04:36
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-iba01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-iba01
[INFO ] Finished pre-update validation on dm01sw-iba01
[SUCCESS ] Pre-update validation on dm01sw-iba01
[SUCCESS ] Prereq check on dm01sw-iba01
[SUCCESS ] Overall status
----- InfiniBand switch update process ended 2019-02-10 03:05:00 -0600 -----
2019-02-10 03:05:00 -0600 1 of 1 :SUCCESS: DONE: Initiate pre-upgrade validation check on InfiniBand switch(es).
2019-02-10 03:02:46 -0600 1 of 1 :Working: DO: Initiate pre-upgrade validation check on InfiniBand switch(es).
----- InfiniBand switch update process started 2019-02-10 03:02:47 -0600 -----
[NOTE ] Log file at /u01/app/oracle/software/exa_patches/patch_18.1.12.0.0.190111/upgradeIBSwitch.log
[INFO ] List of InfiniBand switches for upgrade: ( dm01sw-ibb01 dm01sw-iba01 )
[SUCCESS ] Verifying Network connectivity to dm01sw-ibb01
[SUCCESS ] Verifying Network connectivity to dm01sw-iba01
[SUCCESS ] Validating verify-topology output
[INFO ] Master Subnet Manager is set to "dm01sw-ibb01" in all Switches
[INFO ] Upgrade to 2.2.11_2 requires that the InfiniBand switch be at 2.2.7-2. Upgrading dm01sw-ibb01 first to 2.2.7-2
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-ibb01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-ibb01.
[INFO ] Starting pre-update validation on dm01sw-ibb01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-ibb01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-ibb01, found 26M
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:03:03
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-ibb01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-ibb01
[INFO ] Finished pre-update validation on dm01sw-ibb01
[SUCCESS ] Pre-update validation on dm01sw-ibb01
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-ibb01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-ibb01.
[INFO ] Starting pre-update validation on dm01sw-ibb01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-ibb01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-ibb01, found 26M
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:03:34
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-ibb01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-ibb01
[INFO ] Finished pre-update validation on dm01sw-ibb01
[SUCCESS ] Pre-update validation on dm01sw-ibb01
[SUCCESS ] Prereq check on dm01sw-ibb01
[INFO ] Upgrade to 2.2.11_2 requires that the InfiniBand switch be at 2.2.7-2. Upgrading dm01sw-iba01 first to 2.2.7-2
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-iba01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-iba01.
[INFO ] Starting pre-update validation on dm01sw-iba01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-iba01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-iba01, found 26M
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:04:06
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-iba01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-iba01
[INFO ] Finished pre-update validation on dm01sw-iba01
[SUCCESS ] Pre-update validation on dm01sw-iba01
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-iba01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-iba01.
[INFO ] Starting pre-update validation on dm01sw-iba01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-iba01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-iba01, found 26M
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:04:36
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-iba01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-iba01
[INFO ] Finished pre-update validation on dm01sw-iba01
[SUCCESS ] Pre-update validation on dm01sw-iba01
[SUCCESS ] Prereq check on dm01sw-iba01
[SUCCESS ] Overall status
----- InfiniBand switch update process ended 2019-02-10 03:05:00 -0600 -----
2019-02-10 03:05:00 -0600 1 of 1 :SUCCESS: DONE: Initiate pre-upgrade validation check on InfiniBand switch(es).
- Upgrade the IB Switches using the following command:
[root@dm01db01 patch_18.1.12.0.0.190111]# ./patchmgr -ibswitches ~/ibswitch_group -upgrade
2019-02-10 03:07:26 -0600 1 of 1 :Working: DO: Initiate upgrade of InfiniBand switches to 2.2.11-2. Expect up to 40 minutes for each switch
----- InfiniBand switch update process started 2019-02-10 03:07:27 -0600 -----
[NOTE ] Log file at /u01/app/oracle/software/exa_patches/patch_18.1.12.0.0.190111/upgradeIBSwitch.log
[INFO ] List of InfiniBand switches for upgrade: ( dm01sw-ibb01 dm01sw-iba01 )
[SUCCESS ] Verifying Network connectivity to dm01sw-ibb01
[SUCCESS ] Verifying Network connectivity to dm01sw-iba01
[SUCCESS ] Validating verify-topology output
[INFO ] Proceeding with upgrade of InfiniBand switches to version 2.2.11_2
[INFO ] Master Subnet Manager is set to "dm01sw-ibb01" in all Switches
[INFO ] Upgrade to 2.2.11_2 requires that the InfiniBand switch be at 2.2.7-2. Upgrading dm01sw-ibb01 first to 2.2.7-2
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-ibb01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-ibb01.
[INFO ] Starting pre-update validation on dm01sw-ibb01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-ibb01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-ibb01, found 26M
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-ibb01
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:07:43
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-ibb01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-ibb01
[INFO ] Finished pre-update validation on dm01sw-ibb01
[SUCCESS ] Pre-update validation on dm01sw-ibb01
[INFO ] Package will be downloaded at firmware update time via scp
[SUCCESS ] Disable Subnet Manager on dm01sw-ibb01
[SUCCESS ] Execute plugin check for Patching on dm01sw-ibb01
[INFO ] Starting upgrade on dm01sw-ibb01 to 2.2.7_2. Please give upto 15 mins for the process to complete. DO NOT INTERRUPT or HIT CTRL+C during the upgrade
[INFO ] Rebooting dm01sw-ibb01 to complete the firmware update. Wait for 15 minutes before continuing. DO NOT MANUALLY REBOOT THE INFINIBAND SWITCH
[SUCCESS ] Load firmware 2.2.7_2 onto dm01sw-ibb01
[SUCCESS ] Disable Subnet Manager on dm01sw-ibb01
[SUCCESS ] Verify that /conf/configvalid is set to 1 on dm01sw-ibb01
[INFO ] Set SMPriority to 5 on dm01sw-ibb01
[INFO ] Rebooting dm01sw-ibb01. Wait for 4 minutes before continuing
[SUCCESS ] Reboot dm01sw-ibb01
[SUCCESS ] SUCCESS
[INFO ] Starting post-update validation on dm01sw-ibb01
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-ibb01
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:29:11
[INFO ] /conf/configvalid is 1
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Execute plugin check for Post Patch on dm01sw-ibb01
[INFO ] Finished post-update validation on dm01sw-ibb01
[SUCCESS ] Post-update validation on dm01sw-ibb01
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-ibb01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-ibb01.
[INFO ] Starting pre-update validation on dm01sw-ibb01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-ibb01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-ibb01, found 28M
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-ibb01
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:29:39
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-ibb01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-ibb01
[INFO ] Finished pre-update validation on dm01sw-ibb01
[SUCCESS ] Pre-update validation on dm01sw-ibb01
[INFO ] Package will be downloaded at firmware update time via scp
[SUCCESS ] Disable Subnet Manager on dm01sw-ibb01
[SUCCESS ] Execute plugin check for Patching on dm01sw-ibb01
[INFO ] Starting upgrade on dm01sw-ibb01 to 2.2.11_2. Please give upto 15 mins for the process to complete. DO NOT INTERRUPT or HIT CTRL+C during the upgrade
[INFO ] Rebooting dm01sw-ibb01 to complete the firmware update. Wait for 15 minutes before continuing. DO NOT MANUALLY REBOOT THE INFINIBAND SWITCH
[SUCCESS ] Load firmware 2.2.11_2 onto dm01sw-ibb01
[SUCCESS ] Disable Subnet Manager on dm01sw-ibb01
[SUCCESS ] Verify that /conf/configvalid is set to 1 on dm01sw-ibb01
[INFO ] Set SMPriority to 5 on dm01sw-ibb01
[INFO ] Rebooting dm01sw-ibb01. Wait for 4 minutes before continuing
[SUCCESS ] Reboot dm01sw-ibb01
[SUCCESS ] SUCCESS
[INFO ] Starting post-update validation on dm01sw-ibb01
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-ibb01
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:51:03
[INFO ] /conf/configvalid is 1
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Execute plugin check for Post Patch on dm01sw-ibb01
[INFO ] Finished post-update validation on dm01sw-ibb01
[SUCCESS ] Post-update validation on dm01sw-ibb01
[SUCCESS ] Update InfiniBand switch dm01sw-ibb01 to 2.2.11_2
[INFO ] Upgrade to 2.2.11_2 requires that the InfiniBand switch be at 2.2.7-2. Upgrading dm01sw-iba01 first to 2.2.7-2
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-iba01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-iba01.
[INFO ] Starting pre-update validation on dm01sw-iba01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-iba01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-iba01, found 26M
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-iba01
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:51:38
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-iba01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-iba01
[INFO ] Finished pre-update validation on dm01sw-iba01
[SUCCESS ] Pre-update validation on dm01sw-iba01
[INFO ] Package will be downloaded at firmware update time via scp
[SUCCESS ] Disable Subnet Manager on dm01sw-iba01
[SUCCESS ] Execute plugin check for Patching on dm01sw-iba01
[INFO ] Starting upgrade on dm01sw-iba01 to 2.2.7_2. Please give upto 15 mins for the process to complete. DO NOT INTERRUPT or HIT CTRL+C during the upgrade
[INFO ] Rebooting dm01sw-iba01 to complete the firmware update. Wait for 15 minutes before continuing. DO NOT MANUALLY REBOOT THE INFINIBAND SWITCH
[SUCCESS ] Load firmware 2.2.7_2 onto dm01sw-iba01
[SUCCESS ] Disable Subnet Manager on dm01sw-iba01
[SUCCESS ] Verify that /conf/configvalid is set to 1 on dm01sw-iba01
[INFO ] Set SMPriority to 5 on dm01sw-iba01
[INFO ] Rebooting dm01sw-iba01. Wait for 4 minutes before continuing
[SUCCESS ] Reboot dm01sw-iba01
[SUCCESS ] SUCCESS
[INFO ] Starting post-update validation on dm01sw-iba01
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-iba01
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 04:13:06
[INFO ] /conf/configvalid is 1
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Execute plugin check for Post Patch on dm01sw-iba01
[INFO ] Finished post-update validation on dm01sw-iba01
[SUCCESS ] Post-update validation on dm01sw-iba01
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-iba01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-iba01.
[INFO ] Starting pre-update validation on dm01sw-iba01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-iba01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-iba01, found 28M
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-iba01
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 04:13:35
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-iba01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-iba01
[INFO ] Finished pre-update validation on dm01sw-iba01
[SUCCESS ] Pre-update validation on dm01sw-iba01
[INFO ] Package will be downloaded at firmware update time via scp
[SUCCESS ] Disable Subnet Manager on dm01sw-iba01
[SUCCESS ] Execute plugin check for Patching on dm01sw-iba01
[INFO ] Starting upgrade on dm01sw-iba01 to 2.2.11_2. Please give upto 15 mins for the process to complete. DO NOT INTERRUPT or HIT CTRL+C during the upgrade
[INFO ] Rebooting dm01sw-iba01 to complete the firmware update. Wait for 15 minutes before continuing. DO NOT MANUALLY REBOOT THE INFINIBAND SWITCH
[SUCCESS ] Load firmware 2.2.11_2 onto dm01sw-iba01
[SUCCESS ] Disable Subnet Manager on dm01sw-iba01
[SUCCESS ] Verify that /conf/configvalid is set to 1 on dm01sw-iba01
[INFO ] Set SMPriority to 5 on dm01sw-iba01
[INFO ] Rebooting dm01sw-iba01. Wait for 4 minutes before continuing
[SUCCESS ] Reboot dm01sw-iba01
[SUCCESS ] SUCCESS
[INFO ] Starting post-update validation on dm01sw-iba01
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-iba01
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 04:35:00
[INFO ] /conf/configvalid is 1
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Execute plugin check for Post Patch on dm01sw-iba01
[INFO ] Finished post-update validation on dm01sw-iba01
[SUCCESS ] Post-update validation on dm01sw-iba01
[SUCCESS ] Update InfiniBand switch dm01sw-iba01 to 2.2.11_2
[INFO ] InfiniBand Switches ( dm01sw-ibb01 dm01sw-iba01 ) updated to 2.2.11_2
[SUCCESS ] Overall status
----- InfiniBand switch update process ended 2019-02-10 04:35:25 -0600 -----
2019-02-10 04:35:25 -0600 1 of 1 :SUCCESS: DONE: Upgrade InfiniBand switch(es) to 2.2.11-2.
2019-02-10 03:07:26 -0600 1 of 1 :Working: DO: Initiate upgrade of InfiniBand switches to 2.2.11-2. Expect up to 40 minutes for each switch
----- InfiniBand switch update process started 2019-02-10 03:07:27 -0600 -----
[NOTE ] Log file at /u01/app/oracle/software/exa_patches/patch_18.1.12.0.0.190111/upgradeIBSwitch.log
[INFO ] List of InfiniBand switches for upgrade: ( dm01sw-ibb01 dm01sw-iba01 )
[SUCCESS ] Verifying Network connectivity to dm01sw-ibb01
[SUCCESS ] Verifying Network connectivity to dm01sw-iba01
[SUCCESS ] Validating verify-topology output
[INFO ] Proceeding with upgrade of InfiniBand switches to version 2.2.11_2
[INFO ] Master Subnet Manager is set to "dm01sw-ibb01" in all Switches
[INFO ] Upgrade to 2.2.11_2 requires that the InfiniBand switch be at 2.2.7-2. Upgrading dm01sw-ibb01 first to 2.2.7-2
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-ibb01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-ibb01.
[INFO ] Starting pre-update validation on dm01sw-ibb01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-ibb01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-ibb01, found 26M
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-ibb01
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:07:43
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-ibb01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-ibb01
[INFO ] Finished pre-update validation on dm01sw-ibb01
[SUCCESS ] Pre-update validation on dm01sw-ibb01
[INFO ] Package will be downloaded at firmware update time via scp
[SUCCESS ] Disable Subnet Manager on dm01sw-ibb01
[SUCCESS ] Execute plugin check for Patching on dm01sw-ibb01
[INFO ] Starting upgrade on dm01sw-ibb01 to 2.2.7_2. Please give upto 15 mins for the process to complete. DO NOT INTERRUPT or HIT CTRL+C during the upgrade
[INFO ] Rebooting dm01sw-ibb01 to complete the firmware update. Wait for 15 minutes before continuing. DO NOT MANUALLY REBOOT THE INFINIBAND SWITCH
[SUCCESS ] Load firmware 2.2.7_2 onto dm01sw-ibb01
[SUCCESS ] Disable Subnet Manager on dm01sw-ibb01
[SUCCESS ] Verify that /conf/configvalid is set to 1 on dm01sw-ibb01
[INFO ] Set SMPriority to 5 on dm01sw-ibb01
[INFO ] Rebooting dm01sw-ibb01. Wait for 4 minutes before continuing
[SUCCESS ] Reboot dm01sw-ibb01
[SUCCESS ] SUCCESS
[INFO ] Starting post-update validation on dm01sw-ibb01
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-ibb01
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:29:11
[INFO ] /conf/configvalid is 1
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Execute plugin check for Post Patch on dm01sw-ibb01
[INFO ] Finished post-update validation on dm01sw-ibb01
[SUCCESS ] Post-update validation on dm01sw-ibb01
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-ibb01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-ibb01.
[INFO ] Starting pre-update validation on dm01sw-ibb01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-ibb01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-ibb01, found 28M
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-ibb01
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:29:39
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-ibb01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-ibb01
[INFO ] Finished pre-update validation on dm01sw-ibb01
[SUCCESS ] Pre-update validation on dm01sw-ibb01
[INFO ] Package will be downloaded at firmware update time via scp
[SUCCESS ] Disable Subnet Manager on dm01sw-ibb01
[SUCCESS ] Execute plugin check for Patching on dm01sw-ibb01
[INFO ] Starting upgrade on dm01sw-ibb01 to 2.2.11_2. Please give upto 15 mins for the process to complete. DO NOT INTERRUPT or HIT CTRL+C during the upgrade
[INFO ] Rebooting dm01sw-ibb01 to complete the firmware update. Wait for 15 minutes before continuing. DO NOT MANUALLY REBOOT THE INFINIBAND SWITCH
[SUCCESS ] Load firmware 2.2.11_2 onto dm01sw-ibb01
[SUCCESS ] Disable Subnet Manager on dm01sw-ibb01
[SUCCESS ] Verify that /conf/configvalid is set to 1 on dm01sw-ibb01
[INFO ] Set SMPriority to 5 on dm01sw-ibb01
[INFO ] Rebooting dm01sw-ibb01. Wait for 4 minutes before continuing
[SUCCESS ] Reboot dm01sw-ibb01
[SUCCESS ] SUCCESS
[INFO ] Starting post-update validation on dm01sw-ibb01
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-ibb01
[SUCCESS ] NTP daemon is running on dm01sw-ibb01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:51:03
[INFO ] /conf/configvalid is 1
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-ibb01
[SUCCESS ] Execute plugin check for Post Patch on dm01sw-ibb01
[INFO ] Finished post-update validation on dm01sw-ibb01
[SUCCESS ] Post-update validation on dm01sw-ibb01
[SUCCESS ] Update InfiniBand switch dm01sw-ibb01 to 2.2.11_2
[INFO ] Upgrade to 2.2.11_2 requires that the InfiniBand switch be at 2.2.7-2. Upgrading dm01sw-iba01 first to 2.2.7-2
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-iba01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-iba01.
[INFO ] Starting pre-update validation on dm01sw-iba01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-iba01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-iba01, found 26M
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-iba01
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[SUCCESS ] opensm.conf passed all validations
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 03:51:38
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-iba01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-iba01
[INFO ] Finished pre-update validation on dm01sw-iba01
[SUCCESS ] Pre-update validation on dm01sw-iba01
[INFO ] Package will be downloaded at firmware update time via scp
[SUCCESS ] Disable Subnet Manager on dm01sw-iba01
[SUCCESS ] Execute plugin check for Patching on dm01sw-iba01
[INFO ] Starting upgrade on dm01sw-iba01 to 2.2.7_2. Please give upto 15 mins for the process to complete. DO NOT INTERRUPT or HIT CTRL+C during the upgrade
[INFO ] Rebooting dm01sw-iba01 to complete the firmware update. Wait for 15 minutes before continuing. DO NOT MANUALLY REBOOT THE INFINIBAND SWITCH
[SUCCESS ] Load firmware 2.2.7_2 onto dm01sw-iba01
[SUCCESS ] Disable Subnet Manager on dm01sw-iba01
[SUCCESS ] Verify that /conf/configvalid is set to 1 on dm01sw-iba01
[INFO ] Set SMPriority to 5 on dm01sw-iba01
[INFO ] Rebooting dm01sw-iba01. Wait for 4 minutes before continuing
[SUCCESS ] Reboot dm01sw-iba01
[SUCCESS ] SUCCESS
[INFO ] Starting post-update validation on dm01sw-iba01
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-iba01
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 04:13:06
[INFO ] /conf/configvalid is 1
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Execute plugin check for Post Patch on dm01sw-iba01
[INFO ] Finished post-update validation on dm01sw-iba01
[SUCCESS ] Post-update validation on dm01sw-iba01
[INFO ] ---------- Starting with InfiniBand Switch dm01sw-iba01
[WARNING ] Infiniband switch meets minimal version requirements, but downgrade is only available to 2.2.9-3 with the current package.
To downgrade to other versions:
- Manually download the InfiniBand switch firmware package to the patch directory
- Set export variable "EXADATA_IMAGE_IBSWITCH_DOWNGRADE_VERSION" to the appropriate version
- Run patchmgr command to initiate downgrade.
[SUCCESS ] Verify SSH access to the patchmgr host dm01db01.netsoftmate.com from the InfiniBand Switch dm01sw-iba01.
[INFO ] Starting pre-update validation on dm01sw-iba01
[SUCCESS ] Verifying that /tmp has 120M in dm01sw-iba01, found 246M
[SUCCESS ] Verifying that / has 20M in dm01sw-iba01, found 28M
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-iba01
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 04:13:35
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Verifying that the patchmgr host dm01db01.netsoftmate.com is recognized on the InfiniBand Switch dm01sw-iba01 through getHostByName
[SUCCESS ] Execute plugin check for Patch Check Prereq on dm01sw-iba01
[INFO ] Finished pre-update validation on dm01sw-iba01
[SUCCESS ] Pre-update validation on dm01sw-iba01
[INFO ] Package will be downloaded at firmware update time via scp
[SUCCESS ] Disable Subnet Manager on dm01sw-iba01
[SUCCESS ] Execute plugin check for Patching on dm01sw-iba01
[INFO ] Starting upgrade on dm01sw-iba01 to 2.2.11_2. Please give upto 15 mins for the process to complete. DO NOT INTERRUPT or HIT CTRL+C during the upgrade
[INFO ] Rebooting dm01sw-iba01 to complete the firmware update. Wait for 15 minutes before continuing. DO NOT MANUALLY REBOOT THE INFINIBAND SWITCH
[SUCCESS ] Load firmware 2.2.11_2 onto dm01sw-iba01
[SUCCESS ] Disable Subnet Manager on dm01sw-iba01
[SUCCESS ] Verify that /conf/configvalid is set to 1 on dm01sw-iba01
[INFO ] Set SMPriority to 5 on dm01sw-iba01
[INFO ] Rebooting dm01sw-iba01. Wait for 4 minutes before continuing
[SUCCESS ] Reboot dm01sw-iba01
[SUCCESS ] SUCCESS
[INFO ] Starting post-update validation on dm01sw-iba01
[SUCCESS ] Service opensmd is running on InfiniBand Switch dm01sw-iba01
[SUCCESS ] NTP daemon is running on dm01sw-iba01.
[INFO ] Manually validate the following entries Date:(YYYY-MM-DD) 2019-02-10 Time:(HH:MM:SS) 04:35:00
[INFO ] /conf/configvalid is 1
[INFO ] Validating the current firmware on the InfiniBand Switch
[SUCCESS ] Firmware verification on InfiniBand switch dm01sw-iba01
[SUCCESS ] Execute plugin check for Post Patch on dm01sw-iba01
[INFO ] Finished post-update validation on dm01sw-iba01
[SUCCESS ] Post-update validation on dm01sw-iba01
[SUCCESS ] Update InfiniBand switch dm01sw-iba01 to 2.2.11_2
[INFO ] InfiniBand Switches ( dm01sw-ibb01 dm01sw-iba01 ) updated to 2.2.11_2
[SUCCESS ] Overall status
----- InfiniBand switch update process ended 2019-02-10 04:35:25 -0600 -----
2019-02-10 04:35:25 -0600 1 of 1 :SUCCESS: DONE: Upgrade InfiniBand switch(es) to 2.2.11-2.
- Verify that all the IB Switches are upgraded to latest version.
[root@dm01db01 ~]# ssh dm01sw-ibb01 version
SUN DCS 36p version: 2.2.11-2
Build time: Aug 27 2018 11:18:39
SP board info:
Manufacturing Date: 2014.05.19
Serial Number: "NCDFxxxxx"
Hardware Revision: 0x0107
Firmware Revision: 0x0000
BIOS version: SUN0R100
BIOS date: 06/22/2010
[root@dm01db01 ~]#
[root@dm01db01 ~]# ssh dm01sw-iba01 version
SUN DCS 36p version: 2.2.11-2
Build time: Aug 27 2018 11:18:39
SP board info:
Manufacturing Date: 2014.05.20
Serial Number: "NCDFxxxxx"
Hardware Revision: 0x0107
Firmware Revision: 0x0000
BIOS version: SUN0R100
BIOS date: 06/22/2010
SUN DCS 36p version: 2.2.11-2
Build time: Aug 27 2018 11:18:39
SP board info:
Manufacturing Date: 2014.05.19
Serial Number: "NCDFxxxxx"
Hardware Revision: 0x0107
Firmware Revision: 0x0000
BIOS version: SUN0R100
BIOS date: 06/22/2010
[root@dm01db01 ~]#
[root@dm01db01 ~]# ssh dm01sw-iba01 version
SUN DCS 36p version: 2.2.11-2
Build time: Aug 27 2018 11:18:39
SP board info:
Manufacturing Date: 2014.05.20
Serial Number: "NCDFxxxxx"
Hardware Revision: 0x0107
Firmware Revision: 0x0000
BIOS version: SUN0R100
BIOS date: 06/22/2010
Conclusion
In this article we have demonstrated how to patch Exadata IB Switches using patchmgr utility. Patching an Exadata IB switch is very straight forward and can be done in rolling fashion without any downtime.
I feel extremely cheerful to have seen your site page and anticipate such a large number of all the more engaging circumstances perusing here. Much appreciated yet again for every one of the points of interest. touch switches India
ReplyDeleteNetsoftmate Technical Blog : Step By Step Exadata Infiniband Switch Patching 18C >>>>> Download Now
ReplyDelete>>>>> Download Full
Netsoftmate Technical Blog : Step By Step Exadata Infiniband Switch Patching 18C >>>>> Download LINK
>>>>> Download Now
Netsoftmate Technical Blog : Step By Step Exadata Infiniband Switch Patching 18C >>>>> Download Full
>>>>> Download LINK